CASPLAST CAN-Bus 125

J1939/11

Construction

Type

data cable

Core

bare copper

Insulation

CASFOAM® irradiation cross-linked material

Thermal Characteristics

Operating temperature

-55°C to +125°C

Electrical Characteristics

Operating Voltage

300V

Impedance

120Ω±10%

Production

Range width

twisted pair of 0.5mm², 0.8mm², 18AWG, 20AWG

Drain wire

bare or tin-plated copper

Wrapping

aluminium/mylar

Jacket

modified irradiation cross-linked material

Part No.
Conductor
Conductor Nom. OD(mm)
Dielectric Nom. OD(mm)
Double Insulation
Filler
Finished Cable Nom. OD(mm)
161002C2313
.5mm2 (19/.18) TC
0.89
2.39
Yes
Yes
8.26
161002C2336
.5mm2 (19/.18) BC
0.89
2.39
Yes
No
8.26
161002C2337
18 AWG (19/.23) BC
1.14
3.2
Yes
No
10.11
161002C2365
18 AWG (19/.23) BC
1.14
3.48
No
Yes
8.95
161002C2372
.5 mm2 (19/.18) BC
0.89
2.34
No
Yes
7.00

For more details, please download the sheet.

Downloads

Technical data sheet

General Characteristics

Chemical behaviors

very good resistance to acid, base, mineral oil, and fuel

Mechanical behaviors

excellent cut-through resistance and excellent abrasion resistance

Application

Heavy-duty vehicles

suitable for harsh environments

Standard

SAE J1939/11

Frequently Asked Questions (FAQ)

Yes. This cable is designed and manufactured in accordance with the SAE J1939/11 standard, featuring a controlled impedance of 120Ω ±10% and optimized twisted-pair construction to ensure stable CAN-Bus communication in heavy-duty and industrial applications.

The cable is specifically engineered for harsh environments such as heavy-duty vehicles, industrial automation systems, and agricultural machinery. It offers excellent resistance to oil, fuel, acids, bases, and mechanical abrasion, making it reliable in long-term outdoor or high-stress installations.

Yes. With an operating temperature range from -55°C to +125°C, and irradiation cross-linked insulation and jacket materials, the cable maintains mechanical and electrical stability under extreme cold, heat, vibration, and thermal cycling.

The standard production range includes twisted pairs of 0.5 mm², 0.8 mm², 18 AWG, and 20 AWG. Custom configurations, including conductor size, drain wire type, or shielding structure, are available upon request for specific project requirements.

The aluminium/mylar wrapping combined with a bare or tin-plated copper drain wire provides effective electromagnetic interference (EMI) protection. This shielding design helps maintain signal integrity and reduces data transmission errors in electrically noisy environments.