What is SAE J1939/11 CAN Bus Cable?

SAE J1939/11 is the physical layer standard for CAN bus communication in heavy-duty vehicles, defining specifications for shielded twisted-pair cables operating at 250 Kbps.

Casmo Cable manufactures SAE J1939/11 certified cables with CASFOAM® insulation, rated for −55°C to +150°C, designed for reliable data transmission in automotive, agricultural, and industrial equipment where durability and compliance are critical.

Casmo Cable factory facility, manufacturer of CASPLAST SAE J1939 shielded and unshielded CAN bus cable for heavy-duty vehicle OEMs

CASPLAST CAN-Bus 125

J1939/11

Operating Temperature: -55°C to +125°C

Insulation: CASFOAM® irradiation cross-linked material

Operating Voltage: 300V

Approval: SAE J1939/11

CASPLAST CAN-Bus 150

J1939/11

Operating Temperature: -55°C to +150°C

Insulation: CASFOAM® irradiation cross-linked material

Operating Voltage: 300V

Approval: SAE J1939/11

Why It Matters

Why Your Application Needs SAE J1939/11 Compliance

Standard Compliance

Industry-standard physical layer for heavy-duty vehicle networks (trucks, excavators, agricultural machinery). Ensures interoperability across OEM systems and supplier networks. Required by major manufacturers: Volvo, Caterpillar, John Deere.

Reliability & Durability

Shielded design eliminates electromagnetic interference in high-noise industrial environments. CASFOAM® insulation provides superior temperature stability (−55°C to +150°C range). Twisted pair construction ensures signal integrity over extended cable runs.

Cost Efficiency

Single cable standard eliminates SKU proliferation. Certified compliance reduces re-engineering risk and accelerates product certification. Lower total cost of ownership vs. custom or non-certified alternatives.

Product Lineup

CASPLAST CAN-Bus Series

Two SAE J1939/11 options engineered for different thermal environments.

Specification
CASPLAST CAN-Bus 125
CASPLAST CAN-Bus 150
Operating Temperature
−55°C to +125°C
−55°C to +150°C
Insulation Material
CASFOAM® (XLPE)
CASFOAM® (XLPE)
Operating Voltage
300V
300V
Impedance
120Ω ±10%
120Ω ±10%
Data Rate
250 Kbps
250 Kbps
SAE Certification
J1939/11
J1939/11
Best Application
Trucks, buses (moderate temp)
Engine bay, hydraulic systems (high temp)

Choose CAN-Bus 125 if:

Choose CAN-Bus 150 if:

Technical Detail

Complete Technical Specifications

Full datasheet overview for SAE J1939/11 CAN bus cables.

Electrical Properties

· Impedance: 120Ω ±10%
· Velocity of Propagation: 66%
· Operating Voltage: 300V
· Data Rate: 250 Kbps (SAE J1939 physical layer)
· Shielding: Aluminum foil + drain wire (EMI rejection)
· Conductor Material: Tinned copper

Physical Properties

· Insulation: CASFOAM® (irradiation cross-linked PE)
· Jacket: PVC (flame-retardant)
· Construction: Shielded Twisted Pair (STP)
· Wire Gauge: 18 AWG
· Outer Diameter: 6.5mm ±0.3mm

Temperature & Environmental

· Operating: −55°C to +125°C / +150°C
· Storage: −40°C to +70°C
· Flex Life: ≥1,000,000 cycles (IEC 60811-1-2)
· Oil Resistance: SAE J30R9
· UV Resistance: ASTM G154

Approvals & Certifications

· SAE J1939/11 — Heavy-Duty Vehicle Network
· ISO 6722 — Road vehicle 24V d.c. system
· RoHS 2.0 / REACH Compliant
· ISO 9001 Manufacturing Certification

Applications

Ideal Applications for SAE J1939/11 Cable

Full datasheet overview for SAE J1939/11 CAN bus cables.

Heavy-Duty Trucks

Volvo, Scania, MAN
• Transmission controllers
• Engine control modules (ECM)
• ABS networks

Recommended

CAN-Bus 125 (standard) / 150 (engine bay)

Agricultural Equipment

John Deere, CLAAS, Case IH
• Engine monitoring & telematics
• GPS precision farming

Recommended

CAN-Bus 150 (high engine bay temps)

Construction & Mining

Caterpillar, Komatsu, Volvo CE
• Hydraulic monitoring
• Machine diagnostics

Recommended

CAN-Bus 150 (extreme temps)

Industrial Equipment

Generators & Power Systems
• Generator control systems
• Power distribution
• Building automation

Recommended

CAN-Bus 125 (standard conditions)

Why Choose Casmo Cable for SAE J1939/11?

Trusted by OEM manufacturers worldwide.

Specialized Manufacturing

Direct factory production—we manufacture J1939/11 cables in-house, not reselling. 100% impedance, insulation resistance, and continuity testing per SAE J1939-11. 15+ years in CAN bus cable engineering.

Global Compliance

Certifications: SAE J1939/11, ISO 9001, RoHS 2.0, REACH. Standards: ISO 6722 heavy-duty vehicle compliance. Third-party validated. Consistent quality at any volume.

Engineering Support

Complete datasheets, impedance curves, temperature profiles. OEM-specific custom configurations. Standard 3-4 week delivery. Direct access to our engineering team.

Available Products & Pricing

Trusted by OEM manufacturers worldwide.

CASPLAST CAN-Bus 125 J1939/11

  • Specification: Shielded Twisted Pair, 250 Kbps
  • Temperature: −55°C to +125°C
  • Insulation: CASFOAM® Cross-Linked
  • Impedance: 120Ω ±10%

CASPLAST CAN-Bus 150 J1939/11

  • Specification: Shielded Twisted Pair, 250 Kbps
  • Temperature: −55°C to +150°C
  • Insulation: CASFOAM® Cross-Linked
  • Impedance: 120Ω ±10%

MOQ

305 meters

Lead Time

3-4 weeks

Lengths

Customizable

Packaging

Standard reels

Competitive Edge

Casmo Cable vs Industry Alternatives

Feature
Casmo Cable
Generic J1939
Non-Certified
SAE J1939/11 Certified
✓ Full Certified
Claimed
X
CASFOAM® Insulation
✓ Yes
Standard PE
Standard PE
Max Temperature
+150°C
+125°C
+80°C
Third-Party Tested
✓ Yes
Limited
X
Engineering Support
Direct Access
Generic
Limited
Lead Time
3-4 weeks
4-6 weeks
2-3 weeks
Price Point
Premium
Mid-Range
Budget

Frequently Asked Questions

J1939/11 is for shielded twisted pair at 250 Kbps (engine/transmission networks). J1939/15 is for unshielded twisted pair, used in lower-noise environments. J1939/11 is standard for heavy-duty vehicles where EMI rejection is critical.

Yes. SAE J1939/11 is the standard for any CAN bus physical layer requiring 250 Kbps shielded communication: agricultural equipment, construction machinery, industrial control systems, and marine applications.

Choose −55°C to +125°C for standard under-body routing. Choose −55°C to +150°C if exposed to engine bay, hydraulic systems, or high-heat environments.

Yes. Our SAE J1939/11 cables are 100% compliant with the standard and tested for interoperability with OEM and aftermarket J1939 components.

SAE J1939/11, ISO 9001, RoHS 2.0, REACH, and ISO 6722 compliance. Full test reports and certifications included with each order.

Standard lead time is 3-4 weeks from order confirmation and receipt of manufacturing specifications. Expedited options available upon request.

CASFOAM® is an irradiation cross-linked polyethylene offering: temperature stability across −55°C to +150°C, oil and chemical resistance (SAE J30R9), 1M+ flex cycles, and consistent impedance under thermal stress.

Ready to Upgrade
Your CAN Bus Network?

Contact us