CASPLAST™ RW

4 GKW-AX Plus Flex

Construction

Type

single core power and control cable

Core

tinned fine copper strands, according to VDE 0295 / IEC 60228 Class 5

Insulation

polyolefin copolymer electron-beam cross-linked

Thermal Characteristics

Operating temperature

-40°C to+120°C (fixed)
90°C (moved occasionally)

Electrical Characteristics

Operating Voltage

1.8/3kV

Testing Voltage

6.5kV AC

Production

Range width

0.75 to 400 mm2

Options

Please consult us for any special requirements

Casmo Part No.
Cross section(mm2)
# Strands
Diam. Of Strands(mm)
Final O.D. (mm)
Tolerance(mm)
Approx, Wt..(kg/km)
1120051X
1
32
0.20
2.80
0.4
17
1120051-5X
1.5
30
0.25
3.20
0.4
23
1120052-5X
2.5
49
0.25
3.70
0.4
35
1120054X
4
56
0.30
4.45
0.4
53
1120056X
6
84
0.30
5.05
0.4
76

For more details, please download the sheet.

Downloads

Technical data sheet

General Characteristics

Chemical behavior

very good resistance to acide, base, mineral oil and fuel

Mechanical behavior

excellent cut-through resistance and excellent abrasion resistance

Flame retardant

acc. to EN60332-1-2 / IEC 60332-1-2

Halogen free

acc. to EN 60754-1 / IEC 60754-1

Application

Low smoke

acc. to EN 61034-1-2 / IEC 61034-1-2

Oil-resistant

acc. To EN 60811-404 / IEC 60811-404

Burning behavior

acc. to EN 60332-1-2 / IEC 60332-1-2

Smoke Density

acc. to EN 61034-1+2 / IEC 61034-1+2

Corrosivity of combustion gases

acc. to EN 60754-2 / IEC 60754-2

Rolling stock

power cables with special fire performance used inboards safety circuits, lighting circuits, auxiliary circuits.

Frequently Asked Questions (FAQ)

CASPLAST™ RW 4 GKW-AX Plus Flex is designed for rolling stock applications, including onboard safety circuits, lighting circuits, and auxiliary power circuits. It is suitable for installations requiring enhanced fire performance and reliable electrical behavior up to 3 kV.

Many onboard auxiliary and distribution systems in rail vehicles operate at higher voltage levels than standard low-voltage systems. The 1.8/3 kV rating provides sufficient electrical margin and supports safe, stable operation of critical onboard circuits.

The cable meets stringent fire safety requirements, including flame retardancy according to EN / IEC 60332-1-2, low smoke density according to EN / IEC 61034-1-2, and low corrosivity of combustion gases according to EN / IEC 60754-2. These properties are essential for passenger safety in enclosed rail environments.

With fine-stranded Class 5 conductors and electron-beam cross-linked polyolefin insulation and sheath, the cable offers extra flexibility, excellent cut-through resistance, and high abrasion resistance. This makes it suitable for installations exposed to vibration, movement, and tight routing spaces.

Yes. CASPLAST™ RW 4 GKW-AX Plus Flex provides very good resistance to acids, bases, mineral oils, and fuels. It is also oil-resistant according to EN / IEC 60811-404, supporting long-term reliability in demanding rolling stock environments.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.